Support Document

0 mins to read

September 2024

Document Overview

This document provides guidance on how to interface with various spreader controllers and other in-vehicle sensors commonly installed by Public Works agencies.

All integrations require a GO9 installed in the vehicle along with an IOX-WRKS harness.

Vehicle Assessment Instructions

  1. Request a complete vehicle list from the customer. The list should have the following information for each vehicle:
    1. VIN
    2. Manufacturer
    3. Model
    4. Year
    5. Spreader controller make & model
    6. Temperature sensor make & model
    7. Is the temperature sensor connected to the spreader controller? *
    8. * NOTE: If the temperature sensor is connected to the spreader controller, this data is typically captured through Geotab’s connection to the controller.

    9. Is there any additional equipment that needs to be monitored? (Plows, PTO, lights, etc.) *
    10. * NOTE: Geotab does not provide sensors required to monitor additional equipment.

  2. Perform a typical vehicle analysis to identify which vehicle interface harnesses are required. Refer to the North American Harness Assessment Cheat Sheet.
  3. Refer to the compatibility table in this document to determine which controllers are supported, and what interface cabling is required for each vehicle.

Installation Guides

For detailed installation instructions, refer to

Cable Estimates

NOTE: Geotab does not guarantee that the following suggestions are 100% accurate. They are estimates, and are considered to be best guesses based on experience.

Compatibility Tables

Spreader controllers

Make

Model

Connection Method

Integration Cable

Notes

Accu-Cast

Sample data

Sample data

Sample data

Accu-Cast

All models

No planned support for Accu-Cast controllers. Manufacturer no longer operating, limited support available.

Ace

Sample data

Sample data

Sample data

ACE

Chlorobite

RS232

HRN-FAI

Requires Chlorobite EN-15430-1 Emulator from ACE.

ACE

Ecobite II

RS232

HRN-FAI

Controller Firmware Version 4.6 or newer along with GPS option must be enabled. Clients must work with ACE for any updates required.

Aebi Schmidt

Sample data

Sample data

Sample data

Aebi Schmidt

Stratos I : AL Controller

RS232

Proprietary Cable1

Configure for AL Gateway Datalogging.

Aebi Schmidt

Stratos II : CL Controller

RS232

Proprietary Cable1

Configure for AL Gateway Datalogging.

MFG P/N AA-18-3460308

Aebi Schmidt

Stratos III : ES Controller

RS232

Proprietary Cable1

Configure for EN15430-1:2015.

Bosch Rexroth

Bosch Rexroth

CS 230

RS232

HRN-CS230

Connect external power leads for CS-230 model only.

DO NOT connect external power for CS-230-AC Model.

Bosch Rexroth

CS 440

RS232

HRN-CS440

If the controller has an existing integration cable installed, then a Null Modem Gender changer will be required if the cable has a male connector.

Bosch Rexroth

CS 550

RS232

Proprietary Cable1

Vehicles may already have a cable installed.

If P/N 987400008 is installed, no action required - direct interface

If P/N 987376776 is installed - requires M/F Null adapter

If neither cable is installed order P/N 987400008

Bosch Rexroth

CS 52X

RS232

Proprietary Cable1

Null gender adapter may be required.

If CS-550 Harness is used, connect to Controller Cable Serial Cable labelled “Temp” not the “AVL” or “GPS” cable.

Bosch Rexroth

CS 53X

RS232

Proprietary Cable1

Null gender adapter may be required.

If CS-550 Harness is used, connect to Controller Cable Serial Cable labelled “Temp” not the “AVL” or “GPS” cable.

Bosch Rexroth

CS 660

RS232

Proprietary Cable1

Vehicles may already have a cable installed.

If P/N 987400008 is installed, no action required - direct interface

If P/N 987376776 is installed - requires M/F Null adapter

If neither cable is installed order P/N 987400008

MFG Notes: If the unit has a Knob box or joystick, the ACC port must be used on those as the one on the screen is not operable.

Certified Cirus

Certified Cirus

SpreadSmart RX

RS232

HRN-DB9SI15

Certified Cirus

Dual Spread

RS232

HRN-DB9SI15

Certified Cirus

EZ Spread

N/A

N/A

This model does not support data logging.

Certified Cirus

GL400

RS232

HRN-DB9NM

Requires ATS Gateway2 from Certified Cirus.

Certified Cirus

ACS

RS232

HRN-DB9NM

Requires ATS Gateway2 from Certified Cirus.

Certified Cirus

Freedom 2

RS232

HRN-DB9NM

Confirm controller has RS232 connection for AVL Integration. If there is no connection, client should work with Certified Cirus to install SG07051073.

Controller Firmware 6.0 or greater is required.

Certified Cirus

XDS

RS232

HRN-DB9NM

Recommend Controller Firmware 4.02 or greater.

2 ATS Gateway - For Certified Cirus controllers with this requirement listed, an ATS is required for each vehicle to interface with the Spreader controller. Clients should work with their Certified Cirus Representative to obtain the ATS, appropriate cabling between the ATS and controller as well as any required configuration elements. Geotab will interface with the ATS and not directly with the controller.

Dakota Fluid Power

Dakota Fluid Power

All Models

CANbus

Direct Connection to Controller CAN Network

Customer/Reseller must work with spreader vendor to ensure their controllers are programmed to the Geotab CANbus specification.

DICKEY-john

DICKEY-john

Control Point

RS232

HRN-DB9NM

DICKEY-john

Flex 4

RS232

HRN-FLEX4

DICKEY-john

Flex 4 Pro

RS232

HRN-DB9NM

Proprietary USB-Serial Adapter from DICKEY-john is required

ECON

ECON

All Models

RS232

Male/Female DB9 Null Cable (Self Source)

Note: The HRN-DB9NM can be used however would require a M/F Null Adapter (Self Source).

Epoke

Epoke

Sirius

RS232

HRN-DB9SI15

Epoke

X1

RS232

HRN-DB9SI15

Epoke

Other Data Logging Models

RS232

HRN-DB9SI15

Various models can be configured to output Datalogging with the Epoke RS232-2 format

Force America

Force America

5100 EX

RS232

HRN-FAI

Data is limited if the vehicle does not have a feedback sensor package installed.

RS232 Y Cable may be required if the Joystick option was purchased.

Force America

SSC5100

RS232

HRN-FAI

Datalogging key required to unlock functionality.

Force America

SSC6100

RS232

HRN-FAI

An ELA Module from Force America is required for GEN4 and Older models. GEN5 and newer do not require an ELA module.

Genesis

Genesis

Genesis 1

CANbus

3-Pin J1939 Connection

1939 Y Adapter Kit available from Genesis Upfitter

Genesis

Genesis 2

CANbus

3-Pin J1939 Connection

1939 Y Adapter Kit available from Genesis Upfitter

Genesis

Genesis Pro

CANbus

3-Pin J1939 Connection

1939 Y Adapter Kit available from Genesis Upfitter

Giletta

Giletta

Ecosat

RS232

HRN-GILINT

Muncie

Muncie

MESP402E-CAL

RS232

Proprietary Cable1

Not supported

Muncie

MESP403

RS232

Proprietary Cable1

Not supported

Muncie

Advantage+

CANbus

HRN-DS02Y8

Muncie

Omni/Omni+

CANbus

HRN-DS02S8

Munroe

Monroe

All Models

Not supported

Parker

Parker

IQAN Models

CANbus

Solder connection between Controller H/L and I/O cable CAN lines.

Truck Builder/Dealer must make CANbus H/L Lines available for connection and also need to configure datalogging with the controller as per Geotab specification.

Pengywn

Pengywn

All Models

Not supported

Rasco

Rasco

EPOS 10

RS232

HRN-DB9SI15

Raven

Raven

4400

HRN-DB9NM

*Requires field validation

Scott Industrial

Scott Industrial (Geotab CANbus)

All Models

CANbus

Direct Connection to Controller CAN Network

Customer/Reseller must work with spreader vendor to ensure their controllers are programmed to the Geotab CANbus specification.

1 Proprietary Cable - Indicates interface cable must be obtained from the Manufacturer or Truck Builder

Temperature sensors and mobile weather stations

Make

Model

Connection Method

Integration Cable

Notes

DiCAN

DiCAN

Guardian

RS232

Lufft

Lufft

MARWIS

CANbus

MARWIS Connection Harness with CanBus connection lines required

Solder connection between CanBus H/L Lines. Must include 120 ohm terminating resistor inline.

Precise

Precise

ARC WCM-02

RS232

HRN-DB9SI15 + MF Null adapter

Roadwatch

Roadwatch

Various models

RS232

HRN-DB9SI15

RS-232 Adapter must be acquired from RoadWatch distributor.

Vaisala

Vaisala

MD30

RS232

Additional Controllers

There are many different spreader controllers available in the market. Many controllers (such as controllers for smaller pickup trucks, or basic models for larger trucks) do not provide data logging capabilities for interfacing.

For such controllers, it is usually possible to identify a Spreading On/Off condition via an auxiliary input.